﻿WEBVTT

00:00:01.000 --> 00:00:06.000
All right, so it is one o'clock. So we're going to kick off this training.

00:00:06.000 --> 00:00:15.000
Just to cover some housekeeping rules for today, this training is being recorded and will be offered on demand through CLUIN for those who are not able to join us live.

00:00:15.000 --> 00:00:22.000
The CLUIN training page offers the slides for you to download, and I've also posted a link to the slides in the chat.

00:00:22.000 --> 00:00:30.000
Please use the Q&A box to ask questions, make comments, or report technical problems at any time.

00:00:30.000 --> 00:00:36.000
We will have a question and answer break about halfway through the training as well as at the end of the modules today.

00:00:36.000 --> 00:00:48.000
For those of you who are interested in receiving certificates of completion that will be available upon completion of the feedback form. Once you have completed the form and click the box to certify you participated.

00:00:48.000 --> 00:00:59.000
That certificate will be provided to you. Today's training is sponsored by the Interstate Technology and Regulatory Council, also known as ITRC.

00:00:59.000 --> 00:01:09.000
And is hosted by the US EPA, Cleanup Information Network, also known as CLUIN.

00:01:09.000 --> 00:01:16.000
The Interstate Technology and Regulatory Council is a program of the Environmental Council of States, also known as ECOS.

00:01:16.000 --> 00:01:27.000
Itrc is a state-led organization composed of over 1,000 members from state federal government, the private sector, academia, and community stakeholders.

00:01:27.000 --> 00:01:34.000
Itrc members participate in technical teams which produce tools, resources, and training courses.

00:01:34.000 --> 00:01:47.000
Such as the one you are participating on today. If you'd like to be a part of ITRC, please visit the ITRC website. On our website, you can register for Teams, learn more about how you can be an active member.

00:01:47.000 --> 00:02:01.000
And the full ITRC disclaimer is also available on the website. So if you plan on using Any ITRC materials, we ask that you review the policy in detail And be sure to credit ITRC.

00:02:01.000 --> 00:02:15.000
Itrc is partially funded by the US government. Itrc, nor the US government warranty the material nor endorse any specific products.

00:02:15.000 --> 00:02:21.000
On behalf of the Interstate Technology and Regulatory Council, welcome to today's training.

00:02:21.000 --> 00:02:38.000
Itrc sediment cap, chemical isolation. Guidance document, which is an introduction to the ITRC online resources produced by itrc In 2023.

00:02:38.000 --> 00:02:47.000
On slide five here, I have the pleasure of introducing our trainers today. All of them have served as members on the team and volunteered to support the training offered today.

00:02:47.000 --> 00:02:59.000
If you run into any problems accessing a link during the training, you can navigate directly to the main guidance document And use the table of contents to find the specific trainings we are referencing.

00:02:59.000 --> 00:03:10.000
But at this time, I am going to be handing it off to Ashley Lesser.

00:03:10.000 --> 00:03:21.000
Thank you. I'm excited to welcome you all to our webinar today about the ITRC Sediment cap chemical isolation guidance that was published in 2023.

00:03:21.000 --> 00:03:30.000
There are a number of technical references that are available that discuss different sediment remediation approaches And sediment capping specifically.

00:03:30.000 --> 00:03:39.000
One of those is the 2014 contaminated Sediments remediation Guidance that ITRC previously developed.

00:03:39.000 --> 00:03:44.000
Many of these technical reference materials remain valid and helpful for understanding sediment capping.

00:03:44.000 --> 00:03:54.000
But they tend to have a higher level focus. For example, the 2014 ITRC guidance provides a high-level overview of sediment remediation technologies.

00:03:54.000 --> 00:04:00.000
And it summarizes the key factors that should be considered when evaluating different cleanup options.

00:04:00.000 --> 00:04:05.000
One of the chapters of the 2014 ITRC guidance is dedicated to capping.

00:04:05.000 --> 00:04:10.000
And it provides useful information for deciding whether or not capping could be in a feat.

00:04:10.000 --> 00:04:14.000
Could be an effective remedial approach for any given site.

00:04:14.000 --> 00:04:26.000
Our team supports the information in the 2014 guidance, and we believe it is a valuable resource for projects that are in the alternatives analysis and remedy selection process.

00:04:26.000 --> 00:04:39.000
The new sediment cap chemical isolation guidance was developed to supplement ITRC's 2014 guidance with the goal of improving consistency in the project phases that follow remedy selection.

00:04:39.000 --> 00:04:53.000
Our goal for the guidance was to go into detail about the design, construction, and performance monitoring For the chemical isolation function of CAPS, and to create a framework that could lead to more consistent designs and performance outcomes.

00:04:53.000 --> 00:05:23.000
For CAPS. I'll let Warda continue with an overview of our training for today.

00:05:37.000 --> 00:05:48.000
Hey, Warda. I think something's wrong with your audio and we haven't been able to hear you.

00:05:48.000 --> 00:05:51.000
How about no? Okay. Should I start over, Sabrina?

00:05:51.000 --> 00:05:56.000
Perfect.

00:05:56.000 --> 00:05:58.000
Yeah, I think so. Thank you.

00:05:58.000 --> 00:06:09.000
Okay, thanks for flagging that. Yeah, so as I mentioned, I'll briefly cover the introduction from section one of the guidance and the trainer speaking after me will cover content from the remaining sections of the guidance document.

00:06:09.000 --> 00:06:16.000
And as Ashley mentioned, the 2014 guidance covered remedy selection for contaminated sediment sites in great detail.

00:06:16.000 --> 00:06:23.000
And the graphic shown here on the right outlines the general process to be followed when capping has been selected as part of your remedy.

00:06:23.000 --> 00:06:43.000
You will see this graphic throughout the training as each trainer will use this graphic to identify where we are in the process and which sections of the guidance are related to a particular step in this process.

00:06:43.000 --> 00:06:52.000
So you may have noted that section four was missing from the previous slide. That's because this training is not specifically going to cover Section 4 of the guidance.

00:06:52.000 --> 00:07:00.000
However, the data needs outlined in Section 4 will be touched on throughout the training as they inform all aspects of our discussion.

00:07:00.000 --> 00:07:11.000
Section 4 mainly consists of this table snapshot shown here, table 4-1, which summarizes data needs to support chemical isolation layer design, modeling, construction, and monitoring.

00:07:11.000 --> 00:07:20.000
And you can access this table and look at more details for data needs in the guidance document online.

00:07:20.000 --> 00:07:29.000
So segment capping objectives include physical stabilization to provide physical isolation and prevent particulate contaminant transport.

00:07:29.000 --> 00:07:35.000
Chemical isolation to contain or limit migration and release of dissolved contaminants from underlying sediments.

00:07:35.000 --> 00:07:41.000
And the protection of benthic communities by preventing direct contact with the underlying contaminated sediments.

00:07:41.000 --> 00:07:47.000
These objectives are the same as the capping objectives that were presented in the 2014 guidance.

00:07:47.000 --> 00:07:55.000
However, today's training and the accompanying 2023 guidance focuses on the chemical isolation function of CAPS specifically.

00:07:55.000 --> 00:08:01.000
And with that, I'll hand it over to Bob now to go over the gapping overview.

00:08:01.000 --> 00:08:06.000
All right. Thanks, Verda. Can you all hear me okay

00:08:06.000 --> 00:08:07.000
Perfect.

00:08:07.000 --> 00:08:25.000
Okay, all right. Capping overview. This is section two that provides details on the capping objectives and particularly the chemical isolation function of the cap.

00:08:25.000 --> 00:08:35.000
So capping is a process of placing one or more layers of clean materials or a combination of materials or amendments to meet the objectives that Warga just described.

00:08:35.000 --> 00:08:43.000
The three primary objectives, physical stabilization, chemical isolation, and protection of benthic community.

00:08:43.000 --> 00:08:50.000
These are generally interrelated and can be combined to achieve site-specific performance objectives.

00:08:50.000 --> 00:08:58.000
Now, if site conditions are conducive, then a single layer cap may serve multiple functions to achieve these objectives.

00:08:58.000 --> 00:09:09.000
But in some cases, a multilayer cap system may be required. So in this slide, we have a multiple layer cap system, and I'll go through the function of each of these cap layers.

00:09:09.000 --> 00:09:16.000
I would like to mention here that although this guidance documents is focused on chemical isolation layer.

00:09:16.000 --> 00:09:26.000
But it is important for us to understand the entire CAP configuration because these different cap layers, they do contribute to the design of this chemical isolation layer.

00:09:26.000 --> 00:09:31.000
And Deirdre, our next speaker will go in detail in that section.

00:09:31.000 --> 00:09:36.000
So I'll start with the configuration of this multi-layer cap system.

00:09:36.000 --> 00:09:50.000
The first layer that we are showing right on top of the sediment where is basically a base layer. It's also known as a leveling layer. This layer basically creates even or a stable base.

00:09:50.000 --> 00:09:58.000
On which rest of the cap layers can be placed. It prevents mixing of chemical isolation layer from the contaminated sediments.

00:09:58.000 --> 00:10:10.000
It also provides geotechnical stability and improves cap constructability. Then chemical isolation layer, this is the layer which is the focus of this guidance document.

00:10:10.000 --> 00:10:22.000
This layer is designed to inhibit migration of contaminants from the underlying sediments They're generally a career infection, division, dispersion, bioturbation.

00:10:22.000 --> 00:10:30.000
Or even gas ammunition and design of this layer that depends on the nature of contamination and site conditions.

00:10:30.000 --> 00:10:42.000
Mainly hydrodynamic conditions. Then on top of it is a filter layer, which is intended to mitigate mixing of chemical isolation layer from the upper erosion protection layer.

00:10:42.000 --> 00:10:48.000
This layer is typically used when there is a difference in the grain size of these two layers.

00:10:48.000 --> 00:10:56.000
So it is typically constructed with a medium sized grains or geosynthetic that serves as a transition layer.

00:10:56.000 --> 00:11:05.000
Then erosion protection layer, also known as armor layer. This layer is intended to protect the physical integrity of chemical isolation layer.

00:11:05.000 --> 00:11:13.000
From any anticipated forces that can be caused by hydrodynamic conditions or navigational traffic.

00:11:13.000 --> 00:11:20.000
And this is typically constructed from a range of coarse grain material or Some manufactured materials.

00:11:20.000 --> 00:11:30.000
This guidance does not cover the design of this layer, but we do provide some of the references that can be used.

00:11:30.000 --> 00:11:38.000
Then habitat restoration layer. This is the uppermost layer that accommodates the benthic community after recolonization.

00:11:38.000 --> 00:11:45.000
This layer is the design of this layer may require different stone size or particular grain size.

00:11:45.000 --> 00:11:54.000
It might be addition of some organic material or habitat or substrate to basically promote the habitat in this layer.

00:11:54.000 --> 00:12:01.000
If fines are used, we might need to consider like a thicker layer to account for any loss of sacrificial material.

00:12:01.000 --> 00:12:12.000
And at times it might be required depending on the site specific or project specific requirements that we might need to go back and replenish this there.

00:12:12.000 --> 00:12:19.000
Then surface layer on top of this cap is biologically active zone.

00:12:19.000 --> 00:12:34.000
Which is called BAZ and will be referred throughout this guidance document.

00:12:34.000 --> 00:12:49.000
Right, so a range of cap configurations A range of cab configuration and materials can be used to accomplish performance objectives depending on the site conditions.

00:12:49.000 --> 00:12:56.000
This first column is basically the layers that we just showed on the previous slide.

00:12:56.000 --> 00:13:01.000
The second column represents a scenario where a base layer may not be required.

00:13:01.000 --> 00:13:10.000
For example, in case of dredge and cab. This layer may be required to stabilize any drench residuals prior to capping.

00:13:10.000 --> 00:13:22.000
But in some cases, we may want to play some combination of amendments post dredging to address the contamination and a separate base layer may not be required.

00:13:22.000 --> 00:13:28.000
Then third column shows where a separate habitat restoration layer may not be required.

00:13:28.000 --> 00:13:35.000
This could be the case if the erosion protection layer material provides a suitable habitat for recolonization.

00:13:35.000 --> 00:13:40.000
Or sinus depositioners who are distinct habitat layer may not be required.

00:13:40.000 --> 00:13:55.000
I would like to mention here that erosion protection is important for the sites where there is a potential for camp disturbance due to high hydrodynamic conditions or other erosional factors that can impact the physical integrity of the cab.

00:13:55.000 --> 00:14:07.000
For low energy environment, minimal protection or cover may be required. And in that case, this layer could be constructed with the same material as the habitat restoration layer.

00:14:07.000 --> 00:14:12.000
Then fourth column, in this case, a filter layer may not be required.

00:14:12.000 --> 00:14:20.000
That requirement can be evaluated based on the selection of material for chemical isolation and erosion protection there.

00:14:20.000 --> 00:14:27.000
Then this last one. This configuration is showing a single layer cap system.

00:14:27.000 --> 00:14:32.000
Where a single layer may serve multiple functions and can achieve more than one objective.

00:14:32.000 --> 00:14:42.000
For sites with low potential for chemical migration. A layer of clean materials such as sand or gravel can be used to create a physical barrier.

00:14:42.000 --> 00:14:49.000
Which basically prevent any direct contact of the potential receptors from the contaminated sediment.

00:14:49.000 --> 00:14:57.000
And in this case, then multilayer cap system may not be required.

00:14:57.000 --> 00:15:06.000
The general cap types, these are three most commonly cap types. That includes unamended granular cap.

00:15:06.000 --> 00:15:19.000
Low permeability cap and amended caps. And these are based on the type of material we use for the chemical isolation function of the cap.

00:15:19.000 --> 00:15:25.000
Unlimited granular caps, they are typically constructed of inert materials such as sand, stone.

00:15:25.000 --> 00:15:48.000
Or other natural materials. These caps are permeable in nature. They are generally intended to provide a physical separation and increase attenuation thickness They basically isolate contaminants and prevent direct contact of benthic organisms with the contaminated sediments.

00:15:48.000 --> 00:15:55.000
Low permeability caps, they are typically constructed of clay-based materials or geosynthetic liners.

00:15:55.000 --> 00:16:05.000
These materials are designed to provide relatively impermeable or low permeability barrier that reduces the advective floods of contaminants.

00:16:05.000 --> 00:16:12.000
And these cap also provide physical separation. They also impede upward flow of poor water.

00:16:12.000 --> 00:16:20.000
And migration of contaminants.

00:16:20.000 --> 00:16:25.000
Amended caps, these cap consist of a wide range of reactive amendments.

00:16:25.000 --> 00:16:33.000
These gaps are typically permeable that allow upward flow of pool water and retard chemical migration.

00:16:33.000 --> 00:16:45.000
Selection of amendment depends on the site-specific conditions and contaminants. For organic contaminants, typically activated carbon and organophilic clay-based amendments are used.

00:16:45.000 --> 00:16:55.000
If Nethal is present on site, we might want to use organophilic clays to address any NAPL and activated carbon to address any disulfase.

00:16:55.000 --> 00:17:04.000
Contaminants for sites with heavy metal amendments such as appetite, zeolite, or siderite are typically used.

00:17:04.000 --> 00:17:11.000
There is a table in this section that summarizes these different amendments based on contaminants.

00:17:11.000 --> 00:17:18.000
And there are also different placement techniques. These amendments can be mixed with granular materials such as sand.

00:17:18.000 --> 00:17:24.000
Or they can be applied in commercially available bulk formulations or math-based form.

00:17:24.000 --> 00:17:43.000
And then there are some CAB models that have capability to evaluate these different amendments and Even commercially available formulations And that will be covered later in the training as well.

00:17:43.000 --> 00:17:54.000
Cab design considerations. So this slide illustrates four critical design factors and They will be covered in detail as we make progress through this training, as Verda mentioned.

00:17:54.000 --> 00:17:59.000
So I'll just give a brief overview here. Chemical design criteria.

00:17:59.000 --> 00:18:06.000
It is important for the evaluation of chemical isolation layer thickness and selection of amendments.

00:18:06.000 --> 00:18:13.000
Because that depends on the type of contamination, level of contamination, and hydrodynamic conditions.

00:18:13.000 --> 00:18:18.000
Physical design constraints that's important for design and constructability of cabs.

00:18:18.000 --> 00:18:28.000
We need to understand site settings, navigational requirements. Any geotechnical concerns, presence of debris or structures.

00:18:28.000 --> 00:18:34.000
Any habitat requirements, then we need to have an understanding of hydrodynamic conditions.

00:18:34.000 --> 00:18:53.000
Any erosion potential or slope stability. Then permitting. It's important to understand permitting requirements and errors in the initial planning phase as there could be some requirements that may need to be considered during the design as well as at the time of cap construction.

00:18:53.000 --> 00:19:01.000
And lastly, constructability, it is important to understand the constructability requirements from the initial design phase.

00:19:01.000 --> 00:19:18.000
And to understand how the cap can will be constructed. So if we need to consider any constraints that can be implemented during the design phase, so that cap can be constructed as design and specified.

00:19:18.000 --> 00:19:24.000
And with that, I'll hand it over to Geetra.

00:19:24.000 --> 00:19:34.000
Thanks, Pavna. So as Bhavna just described, there are many different cap types and configurations.

00:19:34.000 --> 00:19:40.000
And with those, we have different amendments that may be needed to meet your site goals.

00:19:40.000 --> 00:19:52.000
So in focusing on the chemical isolation layer. And defining that cap configuration, we often turn to modeling. And Dana Rival is going to talk about that in the next segment of this training.

00:19:52.000 --> 00:20:02.000
So before we turn to the modeling, we need to make some decisions. And that process typically starts with an understanding of your design criteria.

00:20:02.000 --> 00:20:18.000
That is, what are you designing your cap to protect. So in this segment of the training, I'll spend some time talking about the design criteria and other considerations.

00:20:18.000 --> 00:20:26.000
All right. So when we talk about performance targets, the goal often referred to as the remedial action objective.

00:20:26.000 --> 00:20:31.000
Is to reduce the risk to human health or ecological receptors.

00:20:31.000 --> 00:20:38.000
And as you can see in the slide here, these examples, the REOs are pretty broad in nature.

00:20:38.000 --> 00:20:49.000
For example, for human health. Reduce risks to adults and children from incidental ingestion and dermal exposure or consuming contaminated fish and shellfish.

00:20:49.000 --> 00:20:54.000
But when we're designing a cap, we really need the criteria to be more specific.

00:20:54.000 --> 00:21:01.000
More quantitative. And that's where we're going to get into the design criteria.

00:21:01.000 --> 00:21:06.000
So the design criteria, those are the requirements that the cap must satisfy.

00:21:06.000 --> 00:21:13.000
And these components typically answer the questions what where and when.

00:21:13.000 --> 00:21:21.000
So in the examples that we're showing here on the slides, the what are the concentrations or the fluxes.

00:21:21.000 --> 00:21:29.000
The where, so that's the depths that the chemical isolation performance targets apply. And we call that the point of compliance.

00:21:29.000 --> 00:21:39.000
The where is also what spatial scale these apply. And so these could apply over an area-wide basis. So that would be like a SWAC over a specified area.

00:21:39.000 --> 00:21:44.000
Or sometimes we need to apply these targets on a point-by-point basis.

00:21:44.000 --> 00:21:58.000
And then we get to the when, or sometimes we call it or how long. And that's the timeframe that the chemical isolation performance targets apply. And that we call the design life.

00:21:58.000 --> 00:22:07.000
So here are three different examples that show this what, where, and when of the design criteria in practice.

00:22:07.000 --> 00:22:24.000
For example, the poor water concentration of contaminant X shall not exceed one nanogram per liter at a depth of 10 centimeters from the surface of a cap over 100 years. So we have the what, we have the contaminant concentration

00:22:24.000 --> 00:22:32.000
We have one nanogram per liter. We have the where, right, a depth of 10 centimeters. And then we have the how long, 100 years.

00:22:32.000 --> 00:22:39.000
And so the other two examples show the same thing. The second one is an example where we use a flux instead of a concentration.

00:22:39.000 --> 00:22:49.000
And then the third one where you're showing an example with a SWAC instead of a point by point basis.

00:22:49.000 --> 00:22:59.000
So at this time, I'd like you all to think about potential issues that you've encountered When establishing your remedial goals.

00:22:59.000 --> 00:23:12.000
And so I'm going to go into a few examples. One example that I can think of is the uncertainty when the design criteria are based on a solid phase concentration, or you might call it a sediment concentration.

00:23:12.000 --> 00:23:21.000
When we're talking about organic chemicals. And on the next slide, I'll show you an example of what I mean.

00:23:21.000 --> 00:23:35.000
So here we're talking about the what. Those are three questions, the what, the where, and the when. So this is the what. And as I mentioned, the what could be a specific concentration or a flux that needs to be met.

00:23:35.000 --> 00:23:48.000
So for a design criteria that's based on a concentration that must be met, we have two options. We can look at concentrations on a poor water basis or on a solid phase basis.

00:23:48.000 --> 00:23:55.000
And we find it's actually helpful to evaluate performance of a cap either during design or monitoring.

00:23:55.000 --> 00:24:07.000
Based on a poor water basis. And that's because the presence of organic carbon in the cap will influence the concentrations on that solid phase basis.

00:24:07.000 --> 00:24:14.000
On a poor water basis, it's actually easier to understand if the cap is performing as expected.

00:24:14.000 --> 00:24:30.000
So on the left. We're showing an example of a typical cat profile, we have the sediment with cap on top, we have the sand and the BAZ or biologically active zone in the top 10 centimeters.

00:24:30.000 --> 00:24:41.000
And the different lines or the model predicted concentrations At different time frames, 0, 20, 40, 60, 80, and 100 years.

00:24:41.000 --> 00:24:51.000
And so this is a typical profile where the concentrations are the lowest near the surface, which is at the top of the CAP profile.

00:24:51.000 --> 00:24:57.000
And they start to increase as we get closer to that source, which is the sediment.

00:24:57.000 --> 00:25:09.000
Now, the graph on the right is the same exact model simulation. But in this case, the one on the right is showing the solid phase concentration.

00:25:09.000 --> 00:25:20.000
And as you can see with this little call out, the concentrations are increasing at a depth of 10 centimeters and then go down as you get closer to the surface.

00:25:20.000 --> 00:25:29.000
So the reason for that increase that you're seeing in the graph on the right And that you're not seeing in the graph on the left.

00:25:29.000 --> 00:25:41.000
Is that in this model simulation, it's assumed that the biologically active zone Which will start to equilibrate with the surrounding sediments, will have a higher TOC than the sand below it.

00:25:41.000 --> 00:25:48.000
And so once the chemicals start to migrate up into that zone and they start to zorb onto that organic carbon.

00:25:48.000 --> 00:26:01.000
Those concentrations tend to increase, right? So depending on what you assume for your organic carbon concentration in that zone, you may see a higher concentration with a higher TOC.

00:26:01.000 --> 00:26:06.000
Or you may get a lower concentration if you assume a lower TFC.

00:26:06.000 --> 00:26:16.000
And so basically what that's telling us is telling us that the results here are going to be highly impacted by that assumption.

00:26:16.000 --> 00:26:26.000
And by setting the criteria to a poor water basis. We can avoid the effect of that.

00:26:26.000 --> 00:26:37.000
All right, another example of a complicating factor is defining the design criteria can be impacted by the background concentrations.

00:26:37.000 --> 00:26:42.000
In dynamic environments that we often see in rivers or lakes.

00:26:42.000 --> 00:26:50.000
The background concentrations can affect the surface sediment. And therefore, they also can affect the surface of our cap.

00:26:50.000 --> 00:27:03.000
So in this image, we're showing a cap on top of sediment and there's no deposition. No deposition, or if there is deposition, deposition is low concentrations below the RGs.

00:27:03.000 --> 00:27:10.000
The pink line at the bottom, which you see in the sediment, represents a concentration in the pore water.

00:27:10.000 --> 00:27:16.000
What you'll notice is this graph is actually overlaid by an X and Y axis.

00:27:16.000 --> 00:27:27.000
So as we move from left to right. We have increasing poor water concentrations and then we have the depth from the surface along what we call like the y-axis.

00:27:27.000 --> 00:27:35.000
And so what happens over time is that our chemical concentration in the sediment is going to start to migrate up.

00:27:35.000 --> 00:27:44.000
To the surface. Now… On the right.

00:27:44.000 --> 00:28:02.000
We now have an example that shows that the impact from chemicals on depositing materials, right? So this is an example Where we have deposition of more contaminated or more elevated concentrations.

00:28:02.000 --> 00:28:22.000
And here we're going to see as I click through this, we're going to see the impact that those depositing particles will have on the concentrations and you'll see that this pink line is starting to move up, but at the surface, right? So at the bottom, we're seeing the same profile in both cases.

00:28:22.000 --> 00:28:32.000
But when we have depositing particles, you can now see the impact of those depositing particles will have on the concentrations at the surface of our cap.

00:28:32.000 --> 00:28:43.000
And so understanding this and knowing what these concentrations are, those can help you define a more realistic design criteria.

00:28:43.000 --> 00:28:52.000
The other thing is that these graphs also highlight the difference between what we call cap effectiveness and remedy effectiveness.

00:28:52.000 --> 00:29:00.000
So in both cases, the caps are actually behaving similarly, right? The caps are both attenuating the concentrations.

00:29:00.000 --> 00:29:07.000
As we move away from the sediments, we end up seeing decreasing concentrations as we move closer to the surface.

00:29:07.000 --> 00:29:11.000
The only difference is that the one on the right is being impacted by something else.

00:29:11.000 --> 00:29:19.000
Something that a cap can't control. And so what we're seeing is the cap here is performing the same.

00:29:19.000 --> 00:29:23.000
But maybe the remedy is not performing the same in both these.

00:29:23.000 --> 00:29:34.000
Situations. And so by understanding this, we can look later to understand whether our cap is performing by looking at these types of depth profiles.

00:29:34.000 --> 00:29:48.000
And when we talk about that remedy effectiveness. Tomorrow is going to get into this a little bit later in the presentation about how this might affect your long-term monitoring.

00:29:48.000 --> 00:29:59.000
So the next question we need to answer is the where, right? This is the point of compliance which is directly related to our remedial goals.

00:29:59.000 --> 00:30:05.000
So here again, we have a cap on top of underlying sediment. We have a chemical isolation layer.

00:30:05.000 --> 00:30:12.000
And in this case, on top of the chemical isolation layer, we have an erosion protection layer or a habitat layer.

00:30:12.000 --> 00:30:20.000
And within that layer is where we have our biologically active zone In the top portion of that.

00:30:20.000 --> 00:30:27.000
So when the remedial goals are established to be protective of benthic organisms.

00:30:27.000 --> 00:30:33.000
The point of compliance is within or at the bottom of that biologically active zone.

00:30:33.000 --> 00:30:39.000
And this is because that's the zone where the benthic organisms live and feed.

00:30:39.000 --> 00:30:48.000
When we have remedial goals established to be protective of ambient water quality or fish at higher trophic levels.

00:30:48.000 --> 00:30:58.000
We really look at the point of compliance near the surface of the cap where the chemicals will flux to the water column.

00:30:58.000 --> 00:31:07.000
Now, when we do that, though, there's something that we, you know, related to this is what we call the design evaluation depth.

00:31:07.000 --> 00:31:19.000
And so even though we have a point of compliance, we might actually look at a depth different than that point of compliance for which to evaluate the cap effectiveness.

00:31:19.000 --> 00:31:24.000
And this example shows a cap designed, again, to be protective of benthic organisms.

00:31:24.000 --> 00:31:30.000
Therefore, the point of compliance is in the biologically active cell.

00:31:30.000 --> 00:31:34.000
But the design evaluation depth may be different than the point of compliance.

00:31:34.000 --> 00:31:42.000
And that might depend on your environment. There may be reasons to assess cat performance at depths other than your point of compliance?

00:31:42.000 --> 00:31:51.000
Some reasons may include presence of armor stone, or even the confounding effects from deposition.

00:31:51.000 --> 00:31:58.000
And so on the next slides, I'm going to go through some examples of that.

00:31:58.000 --> 00:32:03.000
All right, here's an example of a cap with large armor stone.

00:32:03.000 --> 00:32:09.000
And so what you can see here is a large armor stone. Between it is water.

00:32:09.000 --> 00:32:21.000
And so that armored stone is not likely to provide a lot of attenuation of your chemicals unless it starts filling in with more depositional material.

00:32:21.000 --> 00:32:33.000
So the design evaluation depth in this case may be below the armor stone.

00:32:33.000 --> 00:32:40.000
Now, continuing with that same example of a cap that's designed to be protective of that biologically active zone.

00:32:40.000 --> 00:32:49.000
Once the cap is placed, the benthic organisms are going to reoccupy the top of the cap So the biologically active zone is at the top of the cap.

00:32:49.000 --> 00:32:57.000
And so therefore the point of compliance is in the biologically active zone.

00:32:57.000 --> 00:33:03.000
Now, the point of compliance as we have deposition over time, so moving left to right on this graphic.

00:33:03.000 --> 00:33:19.000
We have increased deposition with time. What's going to happen is that that biologically active zone is going to move with that newly deposited material. So you're going to see that it always stays at the top of the of our cap or deposition.

00:33:19.000 --> 00:33:27.000
If the depositing material is clean. That can contribute to additional natural recovery and provide additional attenuation.

00:33:27.000 --> 00:33:35.000
And in this case, you may choose this as a design evaluation depth as well.

00:33:35.000 --> 00:33:42.000
However, you may choose a design evaluation step that is deeper, avoiding the influence of the depositing material.

00:33:42.000 --> 00:33:57.000
And assessing effectiveness of the CI layer alone to provide attenuation. So that's an example where you may look deeper into maybe the bottom portion of your habitat layer or your erosion protection layer.

00:33:57.000 --> 00:34:10.000
Above the chemical isolation layer.

00:34:10.000 --> 00:34:22.000
Now, this is a case where we have both large armor stone and deposition. And so what's happening here is that you have that depositing material kind of filling in those pore spaces.

00:34:22.000 --> 00:34:34.000
And so this example combines the two scenarios that we just spoke about. And with that infilling, it will behave a little bit more similarly to the deposition example on that last slide.

00:34:34.000 --> 00:34:49.000
And so you could have two points of compliance, either within the deposited material where the biologically active zone exists or somewhere deeper to focus more on the chemical concentrations that are coming right out of that.

00:34:49.000 --> 00:34:55.000
Chemical isolation layer.

00:34:55.000 --> 00:35:02.000
All right. So lastly, we're going to talk about the design life, which answers the question when or for how long.

00:35:02.000 --> 00:35:08.000
And so the design life is the minimum period over which the cap is designed.

00:35:08.000 --> 00:35:18.000
To meet the design criteria. And so CAPS are designed to provide long-term risk reduction.

00:35:18.000 --> 00:35:23.000
And so a typical design life that is widely accepted is 100 years.

00:35:23.000 --> 00:35:31.000
It could be shorter depending on other circumstances. And so this graph shows an example output from CAPSIM.

00:35:31.000 --> 00:35:37.000
Showing predicted concentrations at a depth of five centimeters from the surface of the cap.

00:35:37.000 --> 00:35:52.000
For 100 years simulation. So in this example, the cap was designed to meet the criteria which is shown as that pink line For more than 100 years, and you'll see that the concentrations at 100 years, so at the end of this graph here.

00:35:52.000 --> 00:36:05.000
You'll see that they're still below the criteria, which means that the cap is actually expected to perform at a concentration less than the design criteria for even more than 100 years.

00:36:05.000 --> 00:36:12.000
But just because A CAP is designed for 100 years, which is our design life.

00:36:12.000 --> 00:36:23.000
It's performance life, maybe longer, especially when we include the conservatism that's built into a lot of the design process.

00:36:23.000 --> 00:36:36.000
And there are a number of factors that can affect that conservatism, and I'll discuss those on the next slide.

00:36:36.000 --> 00:36:54.000
So a number of things that enter for the conservatism of our design is our design criteria, right? Often those are just come from risk assessments. Often we build conservatism into those risk assessments.

00:36:54.000 --> 00:37:02.000
In the modeling that's used to define our cap thickness and amendment evaluation.

00:37:02.000 --> 00:37:17.000
The input parameters that are used in those models are often conservative. We usually end up with more conservative seepage rates contaminant concentrations in the pore water and the sediment beneath the cap.

00:37:17.000 --> 00:37:30.000
Our partitioning characteristics. Deposition rates. So those are all things that have the largest influence on our model results, and they tend to be where we add in more conservatism.

00:37:30.000 --> 00:37:39.000
When defining the material specifications, usually we talk about minimum thicknesses and minimum amendment doses to meet the criteria.

00:37:39.000 --> 00:37:56.000
So then during construction, the contractor will often place more than is needed in order to meet those design specifications. And so those are all the places where we build conservatism along the way.

00:37:56.000 --> 00:38:07.000
All right, so now that we've talked about the process of defining our criteria We can get into some of the other factors that affect the design.

00:38:07.000 --> 00:38:16.000
So in this example here, we're going to ask the question, are there any constraints on the cap thickness?

00:38:16.000 --> 00:38:27.000
So examples of constraints include flood control or navigation requirements. And so I'm going to use an example here of the navigation requirements.

00:38:27.000 --> 00:38:33.000
So what we're seeing here is that, you know, given our site, we might have a minimum water depth.

00:38:33.000 --> 00:38:42.000
That's needed for navigation purposes. And so that leaves you with only a certain thickness for the cap.

00:38:42.000 --> 00:38:47.000
So we're going to zoom in on that area that's left for the cap, right?

00:38:47.000 --> 00:38:57.000
And so now we have to start considering what other layers are needed and how much room is left for the chemical isolation layer.

00:38:57.000 --> 00:39:03.000
And so in the guidance document, we refer to this as the top-down approach.

00:39:03.000 --> 00:39:09.000
So we're going to start going through the layers. The first layer, we might need a base layer. Bhavna spoke about that earlier.

00:39:09.000 --> 00:39:20.000
To resist erosive forces, we may need an armor layer. And then depending on the size of that armor layer, you may also need a filter layer.

00:39:20.000 --> 00:39:26.000
And so that leaves only so much space left. For your chemical isolation layer.

00:39:26.000 --> 00:39:41.000
And if this is not enough space, like you can add an amendment to keep that layer thin, or you may need to dredge to make room for that cow.

00:39:41.000 --> 00:39:47.000
So in speaking of the amendments that might be needed to keep that cap thin.

00:39:47.000 --> 00:39:54.000
We cap amendments are often required to meet the performance targets.

00:39:54.000 --> 00:40:01.000
And those amendments depend on the type of COCs. Bhavna talked about them a little bit in her segment.

00:40:01.000 --> 00:40:07.000
And in some cases, a combination of amendments may be needed. It depends on what your COCs are.

00:40:07.000 --> 00:40:18.000
These amendments can be added as discrete layers. They could be mixed with other cat materials Or they can also be directly added to the sediment.

00:40:18.000 --> 00:40:26.000
Sometimes we call that direct amendment. We would suggest that data be collected.

00:40:26.000 --> 00:40:32.000
To support modeling for cap design. So how Zorptive is the amendment at your site?

00:40:32.000 --> 00:40:44.000
And then also we want to consider the benthic community impacts when we talk about what amendments are being placed.

00:40:44.000 --> 00:40:53.000
All right, so section 3.4 of the guidance document provides a comprehensive list of other considerations.

00:40:53.000 --> 00:41:01.000
Listed here are just a few of those, but I really encourage you to spend time reading that section of the document.

00:41:01.000 --> 00:41:10.000
But just to go through a few you may be able to optimize cap design based on spatial differences.

00:41:10.000 --> 00:41:16.000
And so things that could change with space across your site are things like your chemical concentrations.

00:41:16.000 --> 00:41:27.000
Also, the distribution of the contaminants. So this includes the geochemistry, which could also be important for some chemicals, particularly metals.

00:41:27.000 --> 00:41:35.000
The presence of NAPL that could change across your site. Sometimes seepage rates change depending on how large your site is.

00:41:35.000 --> 00:41:43.000
And then also, is it a depositional area, erosional area? And so based on those differences.

00:41:43.000 --> 00:41:51.000
You can maybe divide up your site and optimize different cap types based on that spatial distribution.

00:41:51.000 --> 00:42:09.000
We talked a little bit about that biologically active zone. And so sometimes looking into the benthic community structure and bioturbation Bioturbation depths are often like, you know, on the order of 10 centimeters could be larger depending on your site, more estuarine

00:42:09.000 --> 00:42:25.000
Systems tend to have closer to maybe 15 centimeters But site-specific data may be needed using benthic surveys to sort of inform what you use. And then based on that information and what we talked about earlier.

00:42:25.000 --> 00:42:34.000
That biologically active zone, that thickness, may inform your point of compliance.

00:42:34.000 --> 00:42:40.000
All right. We talked about the design criteria in detail.

00:42:40.000 --> 00:42:53.000
We talked about the different components. We talked about the what the where and the how long We also spoke about some of the complicating factors In cap design and how we might handle those.

00:42:53.000 --> 00:43:03.000
We spoke about the design constraints and we gave an example of that top-down approach that was used for navigation scenario.

00:43:03.000 --> 00:43:11.000
And then finally, I gave some examples of some other site characteristics that can be considered for the chemical isolation layer design.

00:43:11.000 --> 00:43:20.000
And again, there is a lot of information in Section 3 of the guidance document, and I encourage you to spend some time reading that.

00:43:20.000 --> 00:43:27.000
And with that, I will hand it off to Danny Reibel, who's going to talk about the chemical isolation layer modeling.

00:43:27.000 --> 00:43:42.000
Thank you, Jared. So um Let me…

00:43:42.000 --> 00:43:49.000
So chemical isolation layer modeling. I tried to turn on my video.

00:43:49.000 --> 00:43:55.000
Don't necessarily I don't see myself yet, so I'm not sure that's working.

00:43:55.000 --> 00:43:58.000
But if not, we'll just continue on. So isolation layer modeling.

00:43:58.000 --> 00:44:13.000
Debiter talked a lot about some of the key issues that you may want to optimize the processes and the design aspect So that you can, in fact.

00:44:13.000 --> 00:44:26.000
Optimize your system. And that's what we're going to be talking about now with chemical isolation layer modeling.

00:44:26.000 --> 00:44:31.000
I am… So do I have control? There we go.

00:44:31.000 --> 00:44:50.000
Chemical isolation layer modeling. This is the tool, or we're going to talk about the tools that we can use to design our cap and to optimize it. And I'm going to talk a bit about why we're doing modeling, why a specific cap model

00:44:50.000 --> 00:44:54.000
As opposed to a model of the surface or groundwater.

00:44:54.000 --> 00:45:01.000
What tools are available. The important parameters that Deirdre was already alluded to.

00:45:01.000 --> 00:45:07.000
And then a bit about sensitivity uncertainty. You know, we'll say at the outset.

00:45:07.000 --> 00:45:19.000
From all the processes from all the processes aspects of a cap isolation layer, chemical isolation layer, you're not going to have all the information that you'd like to have.

00:45:19.000 --> 00:45:30.000
The question is, do you have enough? To be able to design and optimize your system.

00:45:30.000 --> 00:45:37.000
So some of the things that we might use a model to do We're going to be predicting the performance of the cap.

00:45:37.000 --> 00:45:45.000
Evaluating different designs how thick of a chemical isolation layer do we need? What is that composition? What about amendments?

00:45:45.000 --> 00:45:54.000
Do I need activated carbon? Do I need to worry about powdered carbon versus powdered versus granular carbon.

00:45:54.000 --> 00:46:02.000
Can I use organophilic clay? How do we evaluate what that composition ought to be to meet our design goals?

00:46:02.000 --> 00:46:09.000
Things that we don't necessarily understand very well or we don't have good data on or as good as we'd like.

00:46:09.000 --> 00:46:17.000
Well, an obvious approach to using the model is to evaluate sensitivity to those parameters.

00:46:17.000 --> 00:46:25.000
A model is fantastic for doing exactly that. If we have a range of uncertainty around our groundwater upwelling.

00:46:25.000 --> 00:46:32.000
Well, let's evaluate what it might be over that range. And see what the impact on design might be.

00:46:32.000 --> 00:46:44.000
And then ultimately, once we've constructed this cap, then a model provides us a tool to compare future data, monitoring data. We come back at a five-year review.

00:46:44.000 --> 00:46:50.000
Is it behaving as we expected it? Or are there processes that are causing contaminants?

00:46:50.000 --> 00:46:56.000
To migrate more rapidly through the cap than we had planned and understood.

00:46:56.000 --> 00:47:02.000
Perhaps we need to update the model to deal with that.

00:47:02.000 --> 00:47:10.000
So why specifically CAP models? Probably used to dealing with surface water quality models.

00:47:10.000 --> 00:47:34.000
But the way that they interact with sediments is usually quite simple. They may have several layers of sediment But it's effectively a boundary condition and they're not looking in detail at the processes that occur within the settlements. The same is true in groundwater models. Groundwater models are designed to do exactly that, describe groundwater processes.

00:47:34.000 --> 00:47:40.000
The interface at the sediment interface is in fact just a boundary condition.

00:47:40.000 --> 00:47:50.000
And generally the level of detail is not adequate for trying to address CAP design in either of those.

00:47:50.000 --> 00:47:55.000
There are a variety of unique processes that occur in that upper meter of sediment.

00:47:55.000 --> 00:48:07.000
And we're only really interested typically in that maybe 10 centimeters maybe a meter, but rarely anything that is deeper than that.

00:48:07.000 --> 00:48:17.000
What is effectively a boundary condition for each of those other models is exactly where a cat model is designed to work.

00:48:17.000 --> 00:48:24.000
Let's look at some of those processes that are important and what we might want to use a model to evaluate.

00:48:24.000 --> 00:48:31.000
Certainly the surface water model can tell us about the shear stresses that might be present at the surface.

00:48:31.000 --> 00:48:39.000
And we may need erosion protection. We may need to place cobble or rock.

00:48:39.000 --> 00:48:52.000
At the surface? Well, the CAP model can incorporate that and evaluate what the impact of that might be on processes like hyperic exchange or contaminant migration.

00:48:52.000 --> 00:49:03.000
Certainly, in most situations, we're looking at a stable sediment environment that's not really subject to erosion that we are trying to protect from erosion.

00:49:03.000 --> 00:49:11.000
And therefore, it's what's in the pore water that is what's in the interstitial water, as Deere's already talked about.

00:49:11.000 --> 00:49:24.000
That is causing the migration of contaminants it is groundwater upwelling, it's diffusion in that poor water, it's sorption onto the sediment, sorption onto amendments.

00:49:24.000 --> 00:49:41.000
And then when we get close to the surface, we're having bioturbation occurring we're having really over the whole layer, perhaps significant changes in redox for more oxic at the surface to more reduced below that could have an impact on the

00:49:41.000 --> 00:50:00.000
Fate and migration of your contaminants the near surface environment, it's also important relative to hypereic exchange, especially if we have a granular media, sand or coarser material at the surface, we're going to get a fair amount of hypereic exchange that may

00:50:00.000 --> 00:50:09.000
Impact what depth is actually serving as a chemical isolation layer.

00:50:09.000 --> 00:50:14.000
So these are the sort of things that a model can come and take into account.

00:50:14.000 --> 00:50:22.000
A couple of models that are available, recovery is available from the Army Corps of Engineers, breaks the sediment up into a variety of layers.

00:50:22.000 --> 00:50:29.000
That have different processes that are occurring within each of those layers.

00:50:29.000 --> 00:50:42.000
Primarily dealing with groundwater movement and groundwater movement and absorption and exchange between these various layers.

00:50:42.000 --> 00:50:47.000
We also had CAPSIM, which we have developed at Texas Tech.

00:50:47.000 --> 00:50:56.000
And it is widely used. It has a graphical user interface, which makes it a little bit easier for many people to employ it.

00:50:56.000 --> 00:51:00.000
And again, it breaks the sediment up into a variety of layers.

00:51:00.000 --> 00:51:14.000
That include in the near surface, perhaps hypereak exchange, bioturbation has exchange across the sediment water interface, including perhaps erosion and deposition.

00:51:14.000 --> 00:51:35.000
In that layer. We also have the groundwater upwelling and that modeling of transport in that groundwater as well as both kinetics absorption as well as assumptions of equilibrium. Quite often most people would assume local equilibrium like we often do in groundwater models. And generally that works well

00:51:35.000 --> 00:51:48.000
But if we're trying to answer the question of whether we need powdered carbon or granular carbon because we're worried about kinetics of highly hydrophobic compounds sorption under granular carbon.

00:51:48.000 --> 00:52:03.000
We can assess that within Capsim. We can look directly at the biogeochemical reactions. Well, where do we could we simulate where sulfate reduction is going to occur and where methylation might occur?

00:52:03.000 --> 00:52:10.000
We can do that within Capsim, although I'd have to admit that in most cases, individuals aren't using it for that.

00:52:10.000 --> 00:52:20.000
We tend to make fairly simple assumptions about the sediment that they can support and the nature of the design, the nature of the chemical isolation layer.

00:52:20.000 --> 00:52:26.000
And so most people use it only a portion of Capsim's capabilities.

00:52:26.000 --> 00:52:39.000
One of those capabilities is including commercial materials with realistic values for realistic values the amount of activated carbon or the bulk density of these materials.

00:52:39.000 --> 00:52:51.000
Everything from some materials that are produced by setco to Husker, to Aqua Block.

00:52:51.000 --> 00:53:05.000
Aggregate. These are all materials sediment. These are materials that you may not have much experience with and CAPSIM has their capabilities and their characteristics within the system.

00:53:05.000 --> 00:53:10.000
It also has a variety of estimation tools built into it.

00:53:10.000 --> 00:53:27.000
If you wanted to evaluate kinetics. Well, there are ways of estimating that. If you don't have certain parameter values, well, there are defaults that are usually reasonable that can can be used in the absence of contrary information.

00:53:27.000 --> 00:53:37.000
All that is built into Capsim and Capsim is downloadable from our website.

00:53:37.000 --> 00:53:49.000
Let's talk about, regardless of which model you employ Where do you want to focus your attention? And again, Deirdre's already addressed this as well as the previous speakers to some extent.

00:53:49.000 --> 00:53:58.000
But you will see if you're employing these models that identify, first of all, what contaminant are you going to actually simulate.

00:53:58.000 --> 00:54:14.000
What's the concentration of those contaminants? And in general, you may only have solid concentration and you'll have to use the built-in partitioning tools to calculate what's in that mobile phase, which is the interstitial water.

00:54:14.000 --> 00:54:23.000
But identifying what contaminant has a big effect on what you're design is going to be and certainly the concentration of that contaminant.

00:54:23.000 --> 00:54:35.000
Protecting a benzene from moving into the overlying water is a lot different from protecting for highly hydrophobic organics like PCB 101.

00:54:35.000 --> 00:54:59.000
So understanding which contaminants really are going to control your design. And generally, there's a whole range of contaminants And you most often will identify a subset of that that have a range of concentrations and properties so that you can identify which one actually controls our design at a particular site.

00:54:59.000 --> 00:55:09.000
Because it's so critical to have, especially if we put amendments, it's all about retarded transport through the cap layer.

00:55:09.000 --> 00:55:29.000
So understanding what those sorption coefficients are. If we only have solid concentrations of contaminants, understanding those sorption coefficients that define what moves into the water and will be migrating is extremely important. Now, there are tools built in to evaluate or estimate those using standard approaches.

00:55:29.000 --> 00:55:38.000
But if you have site for specific information on sorption coefficients or good predictions on what they would be in your amended layers.

00:55:38.000 --> 00:55:52.000
Then you should incorporate them. But there are defaults built into Capsim and we have a database of absorption coefficients that could be applied, for example, for activated carbon for many of these compounds.

00:55:52.000 --> 00:56:09.000
Groundwater seepage rates. The number one factor in the number one factor controlling how fast contaminants move through the chemical isolation layer given a contaminant and given sorption coefficients is how fast is the groundwater moving?

00:56:09.000 --> 00:56:26.000
If I'm in a rapidly upwelling area, I'm going to have a much more stringent design than if I'm in an area that is subject to only minimal seepage. And when I say minimal, I'm looking at perhaps centimeter or a month

00:56:26.000 --> 00:56:36.000
Or less of an average upwelling rate. But when I'm in a centimeter a day, I know that that's going to have to be incorporated within the design.

00:56:36.000 --> 00:56:57.000
And if I'm 10 centimeter a day tends to be faster than you normally see in most locations. But if I've got that sort of upwelling rate, it's going to have severe effects on the design as to how I can manage that chemical isolation layer.

00:56:57.000 --> 00:57:04.000
And whether I can even employ capping as an appropriate containment tool.

00:57:04.000 --> 00:57:17.000
Sediment deposition rates are certainly very important. In general, we often or quite commonly we for conservatism, we don't consider deposition.

00:57:17.000 --> 00:57:23.000
But keep in mind, what is deposition doing? It's basically natural capping.

00:57:23.000 --> 00:57:33.000
And as a result, if there is any significant deposition. It just makes the cap work that much better. When we think of enhanced natural recovery systems.

00:57:33.000 --> 00:57:43.000
They're really attempting to perhaps in one year put the equivalent of multiple years of natural deposition on a system.

00:57:43.000 --> 00:57:55.000
So sediment deposition rates are important. Although, again, if we're being conservative, we might not consider or we might not be confident in what a future deposition rate might be.

00:57:55.000 --> 00:58:02.000
And then, as Deirdre's mentioned, this depth within the cap for evaluating the design.

00:58:02.000 --> 00:58:23.000
That is an important selection to make. Often in the near surface, there's a lot going on. There's bioturbation, there's the hypereak exchange, there's exchange across the sediment water interface, often right at the surface, the conditions are not controlled by the chemical isolation layer as much as they're controlled

00:58:23.000 --> 00:58:43.000
By the overlying water. We probably don't want to evaluate a design there. We want to evaluate a design point we want to point point of compliance or we want a point where we're going to evaluate design where the design of the cap actually controls that.

00:58:43.000 --> 00:58:49.000
Which often isn't immediately right at the surface water interface, the sediment water interface.

00:58:49.000 --> 00:58:56.000
So those are key model inputs. There are some other inputs that may be important.

00:58:56.000 --> 00:59:06.000
The intensity of sediment water exchange. Generally, it's not important because we want a point of compliance or a design evaluation point.

00:59:06.000 --> 00:59:14.000
Which isn't right at the sediment water interface. But if we have good mixing at the sediment water interface.

00:59:14.000 --> 00:59:19.000
Then we're going to end up with the actual surface, the interface itself.

00:59:19.000 --> 00:59:38.000
Being controlled by the overlying water. So again, it certainly influences that surface layer of sediment But if our design point or our evaluation point is let's say at the top of the or the bottom of the bioturbation layer or the top of the chemical isolation layer

00:59:38.000 --> 00:59:48.000
Below the sediment water interface, then it's not very important. Kinetics absorption under strongly sorbine phases can be important.

00:59:48.000 --> 01:00:03.000
And especially in those very dynamic upwelling environments let's say a 10 centimeter per day sort of upwelling with a thin layer that contains very little activated carbon.

01:00:03.000 --> 01:00:09.000
Those are the conditions where granular versus powdered carbon can make a difference.

01:00:09.000 --> 01:00:18.000
We also might be looking long term at what happens to these contaminants. Do they react away over time?

01:00:18.000 --> 01:00:34.000
That may be important or it may build confidence. As to the long-term design. But again, for conservatism, we often neglect that But it's something that you could certainly incorporate and certainly incorporate within Capsin.

01:00:34.000 --> 01:00:47.000
To evaluate what it might look like, even these very slow processes that ultimately will render the contaminant inert.

01:00:47.000 --> 01:01:03.000
So interpreting model results, we're not going to talk about how you use the model in this But again, it's just these kind of our key notions that we should have when we're bringing a model to bear.

01:01:03.000 --> 01:01:18.000
Some of the things that should be mentioned in this is that capping is an aerial remedy so that we're we're looking at an area. Maybe we have multiple areas within a site that we're having different designs that we're addressing.

01:01:18.000 --> 01:01:23.000
But we're not looking at a point by point.

01:01:23.000 --> 01:01:33.000
Solution that is I often use the analogy or the metaphor perhaps of a capping is not a balloon.

01:01:33.000 --> 01:01:42.000
If we puncture a hole in it, for example, we're doing some monitoring and we put a core through it It's not like all the contaminants leak out from a cap.

01:01:42.000 --> 01:01:58.000
If we're trying to protect for the 90th percentile concentration and we're trying to protect the overall area for perhaps a 90th percentile criteria.

01:01:58.000 --> 01:02:18.000
Again, capping is ideal and it should be recognized as such it's that we are best evaluating it from the point of view of an aerial remedy, not a point by point worst case. We shouldn't necessarily be designing the entire area for a specific worst case.

01:02:18.000 --> 01:02:31.000
It's important separated out as a sub design. I mentioned before, and it's been mentioned before, that be careful of interpreting competitions right at the cap water interface.

01:02:31.000 --> 01:02:38.000
Because that interface may be controlled by processes in the water, not those that are in the sediment.

01:02:38.000 --> 01:02:43.000
Not in the chemical isolation layer that we're trying to design.

01:02:43.000 --> 01:02:55.000
One aside on that is that the flux at this sediment or the cap water interface at the sediment water interface is controlled by what's happening underneath.

01:02:55.000 --> 01:03:08.000
And so the flux isn't as sensitive to what's happening in the water column, but concentrations certainly are.

01:03:08.000 --> 01:03:19.000
Okay. Trying to move forward.

01:03:19.000 --> 01:03:33.000
There we go. All right. And then finally, relative to sensitivity and uncertainty One of the best one of the best opportunities that a model provides.

01:03:33.000 --> 01:03:40.000
Is the evaluation of the effects of parameters that you don't know very well.

01:03:40.000 --> 01:03:51.000
That are uncertain. You can do a sensitivity analysis and evaluate How does that design that I'm trying to build, how does that respond?

01:03:51.000 --> 01:04:04.000
To that parameter uncertainty and those variation and parameter values. But it's just very important to recognize that we may have a lot of parameters that are uncertain.

01:04:04.000 --> 01:04:10.000
But as I tried to identify before, some of them don't really have an impact on your ultimate design.

01:04:10.000 --> 01:04:17.000
Some of them, like groundwater upwelling, do have an impact design. And so where should we spend our time and effort?

01:04:17.000 --> 01:04:38.000
We should spend our time and effort trying to evaluate those parameters and understand those parameters at a particular site that are not only uncertain, but actually impact our design Those in the upper right-hand box, if you will.

01:04:38.000 --> 01:04:45.000
Turn to the next slide.

01:04:45.000 --> 01:05:07.000
This is just an example output, and Deirdre showed some before of for caps and just showing the sort of information you can have and you can change the what it shows you, this is perhaps a default example of the blue line that's squared off is showing a contaminated layer

01:05:07.000 --> 01:05:15.000
In this case, 45 centimeters below the surface And then as a result of the cap layer.

01:05:15.000 --> 01:05:28.000
With the mixture there that I've called it is activated. Well, it actually has sediment and sand perhaps with a sand layer for erosion protection at the top, and then a biologically active zone of sand at the top.

01:05:28.000 --> 01:05:38.000
And it's just showing the concentration profile as a function of time as it moves into that cat material. So that's the sort of thing that you would have by default.

01:05:38.000 --> 01:05:56.000
But you could also plot flux you could plot solid concentrations. Capsin has the capability of if i put sediment at the surface, it has the potential to describe how that sedemite mixes through bioturbation into the sediment.

01:05:56.000 --> 01:06:14.000
So material transport as well as contaminant transport. Could also be evaluating concentrations or flexes at a particular over time at a particular location as opposed to a flow.

01:06:14.000 --> 01:06:18.000
Plot like this. So you have a variety of options that you can look at your results.

01:06:18.000 --> 01:06:23.000
All the results go into an Excel spreadsheet so you can use those any way that you want.

01:06:23.000 --> 01:06:32.000
To decide whether your design meets the criteria that you're trying to

01:06:32.000 --> 01:06:39.000
Turn to the next slide. And we're going to open it up for some questions, a convenient time for that.

01:06:39.000 --> 01:06:46.000
Thank you.

01:06:46.000 --> 01:06:52.000
All right. Thank you so much, Danny. So now we are going to go to the Q&A just as a review.

01:06:52.000 --> 01:07:07.000
The chat is closed for any of the attendees, but the Q&A is open, so please submit questions at any time and we will answer them now and later on at the end of the modules.

01:07:07.000 --> 01:07:18.000
All right, so I'm going to go over one of the questions that we had answered in text, but just to see if someone wants to elaborate a little bit more.

01:07:18.000 --> 01:07:31.000
Connor asked, can you go into more detail about the mixing consolidation layer. What material exactly is to be consolidated and mixed? Are materials added to the top sediment layer?

01:07:31.000 --> 01:07:37.000
Post dredging if implemented. Would anyone like to elaborate on that?

01:07:37.000 --> 01:07:41.000
I can perhaps elaborate from the point of view of the modeling.

01:07:41.000 --> 01:07:53.000
And the So that in general, when you're placing material the cat material, the chemical isolation layer, erosion protection layer, whatever layers you have.

01:07:53.000 --> 01:07:57.000
On top of very soft sediments, you're going to see consolidation.

01:07:57.000 --> 01:08:16.000
The key issue from the point of view of capping is that that consolidation is expressing pour water up through the cap. So it could be the equivalent of many years of groundwater migration potentially. And so from the point of view of modeling it just evaluating

01:08:16.000 --> 01:08:22.000
How much consolidation you are going to get and what sort of timeframe.

01:08:22.000 --> 01:08:39.000
So for example, a capsim, you were asked to, if you are expecting consolidation you would evaluate how much consolidation would I expect if I have this weight of a cap on top of my soft sediment.

01:08:39.000 --> 01:08:45.000
And what sort of timeframe is it going to achieve 90% of that?

01:08:45.000 --> 01:08:55.000
And so that's what we would use in CAPSIM to evaluate how much poor water is expressed and the contaminant migration that would result from that.

01:08:55.000 --> 01:09:06.000
It tends to be fairly small compared to the volume of water because most chemical isolations layer have significant capacity for sorption.

01:09:06.000 --> 01:09:20.000
So you might have six inches of consolidation and the equivalent of six inches of pore water expressed out But it may only proceed a millimeter or centimeter or two into your cap.

01:09:20.000 --> 01:09:26.000
And compromise that. But that is something that is a consideration that's needed.

01:09:26.000 --> 01:09:32.000
When you're placing these materials on top of a very soft sediment, we would expect.

01:09:32.000 --> 01:09:45.000
Some consolidation. We work hard during placement, as you'll hear about soon, of ensuring uniformity of placement So that we don't have point loading and that we get whatever consolidation we're going to see.

01:09:45.000 --> 01:09:52.000
Is relatively uniform. Over the area.

01:09:52.000 --> 01:09:53.000
Thank you.

01:09:53.000 --> 01:09:59.000
Thank you for that answer, Danny. And we're going to grab one more question and then keep it moving.

01:09:59.000 --> 01:10:07.000
So someone asked What about bodies of water that are spring fed? Won't these springs transport contaminants?

01:10:07.000 --> 01:10:15.000
Through any isolation layer or is the remediation not appropriate in that scenario?

01:10:15.000 --> 01:10:33.000
So again, let me perhaps respond to that is that It is certainly something that is worth considering if you have either bedrock or spring fred groundwater, you know, groundwater movement through bedrock is going to be channeled.

01:10:33.000 --> 01:10:45.000
Into the gaps in the bedrock. So places that you can evaluate that, you can use that as a source of uncertainty in a model and evaluate that.

01:10:45.000 --> 01:11:06.000
Recognize, however, that oftentimes if we have a significant upwelling in a small area This is not the area that's contaminated. The area that has been contaminated is the area where the the at least remaining to be contaminated is where that

01:11:06.000 --> 01:11:13.000
Contamination is not so active or where that upwelling is perhaps not so active.

01:11:13.000 --> 01:11:22.000
If I had a chimney, that's not where I'm going to find those contaminants. So again, it's something to evaluate. It's something to assess.

01:11:22.000 --> 01:11:27.000
But it's The model could be used to do that.

01:11:27.000 --> 01:11:40.000
But if we really have very small areas where the upwelling is channeled to, it's likely those are not the areas that are retaining significant contamination, unless, of course, the groundwater is contaminated.

01:11:40.000 --> 01:11:54.000
So just something to assess as part of the process. To evaluate whether that poses a problem or not.

01:11:54.000 --> 01:12:06.000
Awesome. Thank you again, Danny. So let's keep it moving. We're going to return to the Q&A at the end of the modules. So if you have any questions, please put them in the Q&A.

01:12:06.000 --> 01:12:11.000
And we will answer them as we go written and talk about them later.

01:12:11.000 --> 01:12:18.000
All right, so now I'm going to move this on and pass the controls over to Mike Ellis.

01:12:18.000 --> 01:12:32.000
Thank you. I'm Mike Ellis. I'm a senior environmental engineer with Barr Engineering in Ann Arbor, Michigan. And I'm going to talk about construction considerations for the chemical isolation layer.

01:12:32.000 --> 01:12:39.000
Or section six of the document.

01:12:39.000 --> 01:12:58.000
So we've talked a lot so far about design of the chemical isolate chemical isolation layer in the cap And we wanted to get into constructability considerations and these considerations apply both to implementation of the cap So during actual construction, but also during the design.

01:12:58.000 --> 01:13:05.000
It's important that the design incorporates quality assurance and quality control or QAQ.

01:13:05.000 --> 01:13:14.000
Measures that are implemented during the work to verify that the actual construction of the cap meets the objectives of the design.

01:13:14.000 --> 01:13:24.000
Solve the assumptions in terms of thickness and amendment ratios that are incorporated into the modeling of the cab and the design of the cap are confirmed.

01:13:24.000 --> 01:13:33.000
In the field during construction.

01:13:33.000 --> 01:13:43.000
So on this slide, we have a conceptual figure of layers of the cap similar to what has been shown previously.

01:13:43.000 --> 01:13:50.000
These caps can be fairly complex in terms of having multiple layers in the chemical isolation layer.

01:13:50.000 --> 01:14:06.000
Being just one of those. The layers that we're showing in this conceptual diagram may be made up of the same material or different materials depending on the utility of the material and the objectives of the project.

01:14:06.000 --> 01:14:14.000
One of the main considerations when evaluating cap placement is actual placement of these materials.

01:14:14.000 --> 01:14:22.000
The spread of the materials can vary depending on the equipment that is used and the type of material in the water body.

01:14:22.000 --> 01:14:37.000
In which it's being applied. So the spread of material, it's important to acknowledge to prevent any clumping of material, make sure there's a level surface and Also for geotechnical considerations.

01:14:37.000 --> 01:14:48.000
There are potential that there's requirements for layers to be placed in lifts to make sure that they are geotechnically stable.

01:14:48.000 --> 01:14:55.000
Caps should be built from the bottom up or riverward to shoreward as shown on this slide.

01:14:55.000 --> 01:15:03.000
And that helps prevent creating mud waves that can occur when material is placed on remaining sediment.

01:15:03.000 --> 01:15:09.000
And it prevents those mud waves from recontaminating freshly placed cap materials.

01:15:09.000 --> 01:15:14.000
So building the cap up is an important consideration during construction.

01:15:14.000 --> 01:15:20.000
It's also important that the cap is constructed from upstream to downstream.

01:15:20.000 --> 01:15:25.000
And that's also to prevent recontamination so any mud waves.

01:15:25.000 --> 01:15:38.000
Of impacted sediments created by material placement are migrating downstream rather than upstream into completed portions of the cabinet.

01:15:38.000 --> 01:15:48.000
Another important consideration during construction is mixing of cap materials with the underlying sediment.

01:15:48.000 --> 01:15:54.000
And as shown in this conceptual diagram, we have a mixing or consolidation layer.

01:15:54.000 --> 01:16:00.000
And that can be done to create a level surface for the chemical isolation layer.

01:16:00.000 --> 01:16:07.000
The mixing or consolidation layer may be a separate material. So kind of like a leveling layer.

01:16:07.000 --> 01:16:13.000
Or you may just consider some sort of sacrificial thickness of the chemical isolation layer.

01:16:13.000 --> 01:16:32.000
And that's because it will mix with the underlying sediments and you want to make sure that you have the correct functional thickness of the chemical isolation layer that lines up with the design requirements.

01:16:32.000 --> 01:16:43.000
Another important consideration during construction of the chemical isolation layer is how amendments get mixed in to that material.

01:16:43.000 --> 01:16:59.000
So what's shown on this slide is a conceptual figure showing a sand cap amended with granular activated carbon particles that would be what would be considered well mixed with the sand particles.

01:16:59.000 --> 01:17:09.000
So during the design, design engineers will dictate a dose requirement for the amendment.

01:17:09.000 --> 01:17:28.000
Incorporating that requirement into the project specifications it's in important to consider how that requirement will be verified in the field and making sure that actual dosage is in a matter that could be easily verified in the field, whether that's by weight or by volume or some other

01:17:28.000 --> 01:17:37.000
Measure. The way that it's specified in the project documents is important to consider.

01:17:37.000 --> 01:17:44.000
Another important consideration is that the amendment is well mixed with the aggregate material that it's mixed with.

01:17:44.000 --> 01:17:54.000
And it's important that it is well distributed so the assumptions we made in the chemical isolation layer modeling are correct.

01:17:54.000 --> 01:18:19.000
Put forth in the actual as constructed cap And then verifying the integrity of the amendment can be important. There are certain amendments that may lose their integrity when they are mixed the aggregates. So if there is verification that's needed either prior to or after placement to confirm

01:18:19.000 --> 01:18:25.000
The integrity of the amendment, that's important to incorporate into the project specifications.

01:18:25.000 --> 01:18:40.000
And to confirm in the field. And we want to make sure the amendment is intact, so it functions as designed.

01:18:40.000 --> 01:18:50.000
This slide showcases some of the conventional placement methods used for sediment cap materials, and I'll just step through each of those.

01:18:50.000 --> 01:19:10.000
First, we have on this slide is a concrete bucket It's good to use for shoreline applications and you can have a fairly high production rate. However, it is uh it does require shoreline access by accrue, which is showcased in a showcase

01:19:10.000 --> 01:19:18.000
This photo. And there are some difficulties associated with lift control.

01:19:18.000 --> 01:19:31.000
Another option is placement of cap materials with an excavator. Some advantages here are that these This equipment is commonly available and can be used both from shore or from a barge.

01:19:31.000 --> 01:19:41.000
This method also has some difficulties with lift control and fairly little production rates.

01:19:41.000 --> 01:19:46.000
A clamshell bucket is another option for placement of cap materials.

01:19:46.000 --> 01:19:54.000
This is commonly available marine equipment and can result in higher production rates because of the bucket volume.

01:19:54.000 --> 01:20:03.000
However, the disadvantages is that the disadvantages a lot of clearance is needed for a clamshell bucket operated from a crane like what's shown.

01:20:03.000 --> 01:20:14.000
In this photo, if you can imagine that wouldn't function well if there's overhead bridges or utilities or anything like that.

01:20:14.000 --> 01:20:22.000
And another common delivery method is a conveyor, which is shown in the photo on the far right hand side of the slide.

01:20:22.000 --> 01:20:33.000
This method can have a fairly high production rate. However, you do need to find a way to continuously deliver material to the actual conveyor.

01:20:33.000 --> 01:20:51.000
To take advantage of those production rates and that can be difficult along with delivery from the conveyor to the actual desired placement location.

01:20:51.000 --> 01:20:58.000
In addition to some of the typical placement methods, we also wanted to highlight a few proprietary methods.

01:20:58.000 --> 01:21:07.000
Several sediment remediation contractors have their own proprietary app placement equipment.

01:21:07.000 --> 01:21:18.000
And that can be really beneficial because it takes advantage of all their years of experience in the field and knowing what works well and what doesn't work well.

01:21:18.000 --> 01:21:23.000
So we've included two examples of those proprietary systems on this slide.

01:21:23.000 --> 01:21:39.000
On the left is a spreader system with hydraulic delivery. So cap material is delivered hydraulically to the spreader barge And then that material is spread in a moon pool configuration.

01:21:39.000 --> 01:21:52.000
That allows for a or even distribution of cat materials in a fairly big area relative to what you would get from like a clamshell bucket or an excavator bucket.

01:21:52.000 --> 01:22:01.000
So the advantage of a system like this is that it has a high production rate and fairly even distribution of cat materials.

01:22:01.000 --> 01:22:15.000
However, it's hard to implement in tight spaces. As you can imagine, the mood bowl configuration can prevent it from getting into corners or where there's ridge abutments or things like that.

01:22:15.000 --> 01:22:24.000
On the right is another proprietary system from different contractor. It's pretty similar, however.

01:22:24.000 --> 01:22:28.000
It doesn't have a trying step, which is the one on the left does.

01:22:28.000 --> 01:22:36.000
So the system on the right has hydraulic delivery of the cap materials and then placement in the pool configuration.

01:22:36.000 --> 01:23:06.000
So pretty similar advantages and disadvantages to this system. Both of these systems we'll need to consider qualities of the water body, things like any currents, things like that that could result in high turbidity from material being spread out and placed in thin lifts.

01:23:07.000 --> 01:23:12.000
We want to highlight a few key issues related to placement.

01:23:12.000 --> 01:23:17.000
And material loss as well.

01:23:17.000 --> 01:23:24.000
So for material placement and accuracy, it's really key to consider operator experience.

01:23:24.000 --> 01:23:32.000
Their experience can have a major factor in the quality of the placement and the accuracy of the material placement.

01:23:32.000 --> 01:23:51.000
And as I mentioned in the previous slides, the type of equipment used for placement has a significant impact on the accuracy verifying or evaluating contractors proposed placement method is an important step.

01:23:51.000 --> 01:24:10.000
When bidding out a project. It's also important to have substantial quality control measures incorporated into the project specifications that allow for accurate tracking of material placement during construction.

01:24:10.000 --> 01:24:17.000
I want to know things like where lifts are placed, the quantity that's placed, and the uniformity of the placement.

01:24:17.000 --> 01:24:35.000
In the next slide, I'll talk through some potential methods for potential verifying placement of cat materials But kind of standard practice includes use of RDK, GPS enabled equipment and routine bath metric surveying.

01:24:35.000 --> 01:24:42.000
As well as some other direct measurements.

01:24:42.000 --> 01:24:49.000
Another important consideration during construction is material loss.

01:24:49.000 --> 01:25:01.000
Implementing contractors will need to consider material loss when evaluating the quantity of material needed for the project. So that'll impact their costs as well.

01:25:01.000 --> 01:25:16.000
Some things to consider when evaluating how significant of an impact material loss will be on a project is material properties. So that's properties that cap material, equipment accuracy, and placement conditions.

01:25:16.000 --> 01:25:24.000
And when executing a project, you want to be realistic about material loss. It's something that is going to happen.

01:25:24.000 --> 01:25:42.000
We'll need to find ways to control it with water quality controls in a way to verify that actual placement meets the project requirements for thickness of each layer of the sediment cap.

01:25:42.000 --> 01:26:05.000
Another consideration is that consideration is that different materials in the cap may have different tendencies for being lost during placement so materials with a lower bulk density have a tendency to drift during cat placement, whereas materials with a higher bulk density um

01:26:05.000 --> 01:26:13.000
Tend to fall out of the water column quicker and less tendency for being for being lost.

01:26:13.000 --> 01:26:35.000
In scenarios where CAP has an amendment That's really important to consider how that amendment is placed, things like activated carbon can have fairly low density um have a tendency to separate out during placement

01:26:35.000 --> 01:26:55.000
So this slide highlights a few standard placement quality assurance methods, and I'll step through each of those But before doing that, just wanted to note that there's no one right answer for what makes up a good QA, QC program for implementing a sediment cap.

01:26:55.000 --> 01:27:03.000
It's very dependent on site conditions, the cap design objectives and objectives of the project.

01:27:03.000 --> 01:27:16.000
So these can all be considered various tools in the toolbox and selected as needed based on site-specific or project-specific requirements.

01:27:16.000 --> 01:27:22.000
So bathymetric survey is a tool that is commonly used to verify placement of CAP materials.

01:27:22.000 --> 01:27:30.000
The advantage here is that it gives you an area-wide evaluation of placement And it's commonly available.

01:27:30.000 --> 01:27:41.000
But some disadvantages are that it's not going to evaluate any mixing of CAP with the underlying sediments or amendment additions.

01:27:41.000 --> 01:28:04.000
So bottom profile is another method that's fairly commonly used. What it does is image the image sediment so you can detect different layers of a sediment cap, which is important when evaluating thickness However, it does not provide any information

01:28:04.000 --> 01:28:13.000
The amendment addition and it is very location specific so you're not getting that area-wide assessment.

01:28:13.000 --> 01:28:31.000
Sediment profile imaging. Is another tool that's commonly used this provides view of the in-place material so you can confirm mixing thickness as well as distribution of any amendments that are used in that layer of the cap.

01:28:31.000 --> 01:28:45.000
However, the disadvantage is that it is location specific, so you're only getting information at one specific point and that might vary significantly throughout the project area.

01:28:45.000 --> 01:28:55.000
And there's a limited thickness that you can conduct those subsurface images below the top of sediment.

01:28:55.000 --> 01:29:14.000
Settling pans are a common and pretty simple way to evaluate cap placement. So these can be buckets or pans that are placed prior to placement of any cap materials and then following placement of the cap layer the pans are removed from the water column.

01:29:14.000 --> 01:29:22.000
Material that's collected in the pan can be evaluated for thickness or amendment addition.

01:29:22.000 --> 01:29:34.000
Some disadvantages of this method is that it is location specific and it's not able to evaluate any settling or mixing.

01:29:34.000 --> 01:29:41.000
Collection of cores following placement of cap materials is another commonly used method.

01:29:41.000 --> 01:29:51.000
This does give you information on the thickness amendment addition rates, as well as mixing with underlying sediments.

01:29:51.000 --> 01:30:13.000
And again. Disadvantage for this method is that it is location specific and there's potential that cap materials are going to consolidate or get compressed in the core, which will affect the evaluation of their thickness.

01:30:13.000 --> 01:30:20.000
So to wrap up the construction consideration section, I wanted to highlight a few key takeaways.

01:30:20.000 --> 01:30:42.000
The first is that evaluation of proposed equipment and contractors prior to starting the work is an important step As I mentioned, operator experience and the method used for placement of cat materials can have a significant impact the quality of the construction.

01:30:42.000 --> 01:31:06.000
Another key takeaway is that controlled placement of sediment cap layers is important to mitigate potential recontamination of cat materials. So following those steps of riverward to shoreward and upstream to downstream is important prevent recontamination of materials.

01:31:06.000 --> 01:31:28.000
Also, amendment delivery is an important consideration in sediment projects where there is an embedded cap making sure the amendment is well mixed and both prior to and following placement of the material is important to make sure the cap is going to function as designed.

01:31:28.000 --> 01:31:33.000
And then finally, development of robust quality assurance program is important.

01:31:33.000 --> 01:31:43.000
This needs to be site specific and needs to meet goals of the project and tailored to the sediment cap design.

01:31:43.000 --> 01:31:51.000
So fedding of the quality assurance program with contractors prior to construction is important to make sure it's implementable.

01:31:51.000 --> 01:31:57.000
And also that it will result in data that's needed to confirm.

01:31:57.000 --> 01:32:06.000
Construction of the sediment gap.

01:32:06.000 --> 01:32:24.000
And with that, I'll pass it on.

01:32:24.000 --> 01:32:28.000
Hi, can everyone hear me? Okay, good.

01:32:28.000 --> 01:32:33.000
Foud and clear.

01:32:33.000 --> 01:32:39.000
A lot of… problems with teams today.

01:32:39.000 --> 01:33:03.000
So… This here, we are back at our you know kind of general outline of this outline of this guidance document and the last session, which I'm going to cover is once all of this work has been done and you have your cap and it's in place

01:33:03.000 --> 01:33:11.000
What you need to do in order to make sure that your cap remains effective and is working the way intended.

01:33:11.000 --> 01:33:19.000
Next slide.

01:33:19.000 --> 01:33:25.000
So I'm trying to… Okay.

01:33:25.000 --> 01:33:35.000
There are… a variety of ways that you can use monitoring to determine CAP performance.

01:33:35.000 --> 01:33:45.000
One of them obviously is to make sure that the installed cap conforms with the performance design.

01:33:45.000 --> 01:34:09.000
The other is to look at the chemical migration to determine whether the cap is performing its chemical isolation features And then you do want to look at natural recovery, which is resedimentation, repopulation by your naturally occurring bentos And then do you need to maintain or repair your cap over

01:34:09.000 --> 01:34:14.000
It's lifetime And what is that lifetime?

01:34:14.000 --> 01:34:26.000
Bearing in mind that a cap like any other built infrastructure is an engineered product And that it needs some attention over time and may need some repair.

01:34:26.000 --> 01:34:35.000
Or refurbishment to make sure that it is in place and continuing to perform as designed.

01:34:35.000 --> 01:34:41.000
Next slide.

01:34:41.000 --> 01:35:04.000
So there are a bunch of different ways that we can look at the chemical isolation feature of the cap the you know you have these different layers that we've gone over this earlier in this course And you can first of all, see whether in fact

01:35:04.000 --> 01:35:24.000
You have these layers in place and then looking at your chemical isolation layer that is sort of your canary in the in the coal mine because that is really where your functionality for chemical isolation should be occurring so that is

01:35:24.000 --> 01:35:32.000
Definitely a place to to monitor. And then the question becomes, well, what is a good way to do so?

01:35:32.000 --> 01:35:40.000
Next slide.

01:35:40.000 --> 01:36:01.000
So you may have seen this earlier What we're looking at here is if you did something like poor water monitoring and you're looking at your chemical of concern concentrations. And when we say cap thickness here, we're really looking at the depth

01:36:01.000 --> 01:36:08.000
Of the cap. So the first one shows what you would expect if everything is performing optimally.

01:36:08.000 --> 01:36:38.000
As you get shallower, you have less and less of your observed contaminant which shows that your isolation function is working. The middle one shows that you do have declining concentrations, but they're certainly not going to zero, which means that some aspect of the chemical isolation feature is not performing optimally.

01:36:40.000 --> 01:36:47.000
Then you look at the last one, and that's kind of tricky and you see that at the bottom and the deeper layer, it looks identical.

01:36:47.000 --> 01:37:06.000
To the optimally performing cat, but then all of a sudden you have increasing levels of your contaminant and that is typically not an indication that you are chemical isolation is not working, but rather that you have recontamination and then that goes to the whole

01:37:06.000 --> 01:37:18.000
Issue of background and that would be something where you know you may not be achieving your remedy, but it's not a problem with your cat.

01:37:18.000 --> 01:37:44.000
So hopefully you don't see that and that your investigation prior to implementing the cap have to you know have have ruled out you know the recontamination concern that you may get but a lot of the things that we design chemical isolation for are very common in the environment so

01:37:44.000 --> 01:37:53.000
Can often expect some level of decontamination. Next slide.

01:37:53.000 --> 01:38:16.000
So what exactly do we want to measure? So the previous slide looked at pour water, poor water being, of course, your dissolved phase. That is where you expect your soluble migration to occur. And that's kind of the gold standard for what you would look for. Can you actually

01:38:16.000 --> 01:38:39.000
Measure the solid phase, your bulk sediment you can But then if you have a situation like the third issue where you have an issue where background recontamination, it's not really going to measure the performance of your chemical isolation function, it's just going to tell you

01:38:39.000 --> 01:39:04.000
What your contamination is and you know if you have a very unusual contaminant or something that you have already confirmed is not likely to be in background, it can be a much easier, less expensive thing to look for but you know if we're talking about common metals, PCBs, pesticides, things we see all the time, you do want to be careful.

01:39:04.000 --> 01:39:19.000
And then surface water, I have seen a lot of projects where we do measure surface water I'm not crazy about it because surface water, obviously, especially in a larger system.

01:39:19.000 --> 01:39:43.000
Tends to move so much and there's so much dilution that it's really unlikely that anything you measure is going to reflect your chemical isolation function of your cap. It might be an exception if you have something like a a wetland where you don't have a huge amount of water and you have a very low energy system

01:39:43.000 --> 01:39:52.000
Where your breakthrough might be mixing with surface water and could become detectable but In general, not a great tool.

01:39:52.000 --> 01:39:59.000
And then we have biota. And as an aside, when this team first met several years ago.

01:39:59.000 --> 01:40:09.000
And we started talking about fish, it became very heated. And at one point, somebody even said, you know, next person who says fish is banished. He doesn't get lunch.

01:40:09.000 --> 01:40:14.000
So, you know, a lot of agencies really do want to see fish.

01:40:14.000 --> 01:40:22.000
Because sediment remedies, often fish, whether it's for wildlife food chain.

01:40:22.000 --> 01:40:33.000
Or for human health consumption, fish are a very important endpoint and fish contamination is something that we're really trying to clean up for.

01:40:33.000 --> 01:40:42.000
That said, fish, of course, do also move around a lot in larger systems. You have fish that spend only a tiny fraction of their lifespan.

01:40:42.000 --> 01:41:04.000
In what may be your site area, some of the larger fish that humans eat may be anagromous, they're going out to the ocean and back upstream. So it's really hard to know whether what you're seeing in fish is In fact, reflective of what is going on in your remedial area.

01:41:04.000 --> 01:41:30.000
The other issues that unfortunately bioaccumulation of some contaminants you know like pcbs dioxins and And more recently, PFAS are a major issue They bioaccumulate and they those magnification factors are so high that just because of the way the food chain is.

01:41:30.000 --> 01:41:42.000
And because of the age of the fish or a variety of other physical chemical processes, it takes a really long time for the fish to reflect an improvement in the sediment.

01:41:42.000 --> 01:41:56.000
Qualities. If you're in a site where there is a desire to monitor fish, I would just say that it's best to hold off.

01:41:56.000 --> 01:42:08.000
If you can measure fish at five years, 10 years, 20 years, see if things are getting better. And they will But it's certainly not straightforward.

01:42:08.000 --> 01:42:14.000
And if you're being asked to measure fish a few months after your cap is in place.

01:42:14.000 --> 01:42:21.000
Guarantee you're not going to see anything that reflect how well your cap is performing.

01:42:21.000 --> 01:42:27.000
Next slide. Moving on to maintenance.

01:42:27.000 --> 01:42:57.000
Again, your cat may be great, may be there till the end of time or with increasing concerns with more storm activity sea level rise and then you have man-made influences like like boats, prop wash You know, things that wrecks at the bottom, you never know what could be down there. And all of that could impact

01:42:57.000 --> 01:43:15.000
The integrity of your cap certainly if you start to see migration of your chemicals You mentioned pour water, for example, that could be a clue that you need to go out and take a look and see also what is the elevation your bathymetry

01:43:15.000 --> 01:43:39.000
Of the cat, you see a lot of consolidation or settling that you know some subsidence could suggest that you know the cab integrity is failing. And of course, anything on a slope could show degradation. It is, however, worth pointing out that a small area of the calf

01:43:39.000 --> 01:44:03.000
That looks like it's like you know collapsing or collapsing you know you know that it's disintegrating in some way doesn't necessarily mean that your cat has failed These are area-wide remedies and your oral cap performance may be fine even if you have a little degradation around the edges or in certain

01:44:03.000 --> 01:44:09.000
Location. So it's not like, you know, it has to be pristine. It's a judgment call. Is it still working?

01:44:09.000 --> 01:44:33.000
Is it still in the place where it was constructed? Those are the things you're looking for. But your monitoring plan should include some kind of trigger or criterion for when you might want to go out and do maintenance. So like anything else, it's good to have something there a benchmark

01:44:33.000 --> 01:44:42.000
That you can rely on so that you know whether or not you really need to go out and do some kind of repair.

01:44:42.000 --> 01:44:55.000
Next slide. So overall, you know, you think of your cat the way you would a treatment plant or any kind of built acid. It is an engineered product.

01:44:55.000 --> 01:45:07.000
So, you know, keep an eye on it. Develop criteria. Think about things that are fairly easy to measure and monitor.

01:45:07.000 --> 01:45:12.000
And think about how often you're going to take those measurements.

01:45:12.000 --> 01:45:17.000
And then think about what your responses are going to be. Are you going to monitor more frequently?

01:45:17.000 --> 01:45:39.000
Are you going to evaluate whether it's really a problem or do you need to go out and make some kind of physical repair. And finally, as I noted you do want to make sure that you're not overreacting and local deviations are really not necessarily a problem for your overall CAP performance.

01:45:39.000 --> 01:45:49.000
Next slide. So with this, I'm going to turn it back over to Ashley to conclude this uh

01:45:49.000 --> 01:45:55.000
Thank you, Tamara and my fellow team members who have presented today.

01:45:55.000 --> 01:46:08.000
Our goal for this sediment capping guidance was to expand on the 2014 sediment remediation guidance by developing a comprehensive understanding of the design, construction.

01:46:08.000 --> 01:46:14.000
And long-term monitoring and maintenance of caps. With a focus on the chemical isolation function.

01:46:14.000 --> 01:46:21.000
So to recap. Designing the chemical isolation function is an iterative process.

01:46:21.000 --> 01:46:34.000
That begins with understanding remedial goals and objectives. We use those objectives to develop a chemical design criteria specific to the contaminant fate and transport pathways within the CAP.

01:46:34.000 --> 01:46:41.000
Chemical design criteria. Are, the what, the where, and the when Or for how long.

01:46:41.000 --> 01:46:47.000
That serve as the conditions that the design needs to meet to satisfy the remedial objectives.

01:46:47.000 --> 01:46:57.000
Once these design criteria are developed. Cap design involves selecting appropriate capping materials and thicknesses to achieve those design criteria.

01:46:57.000 --> 01:47:04.000
In addition to the chemical design criteria. It is important that the cap also satisfy other design factors.

01:47:04.000 --> 01:47:09.000
Such as physical constraints. Permitting and other regulatory requirements.

01:47:09.000 --> 01:47:19.000
And it must remain constructible. There are two available monitoring tools that have been developed specifically to support capping design.

01:47:19.000 --> 01:47:28.000
And these modeling tools can be used to estimate how well various CAP configurations and materials can achieve the design criteria.

01:47:28.000 --> 01:47:42.000
Once the design is completed. It is important to convey cap construction requirements clearly to contractors and to employ construction quality assurance measures to verify that the built cap is consistent with the design.

01:47:42.000 --> 01:47:48.000
Finally, after construction, it's important to factor in how CAP performance will be monitored.

01:47:48.000 --> 01:47:53.000
Potentially in addition to other effectiveness monitoring approaches for the remedy.

01:47:53.000 --> 01:48:16.000
We recommend that CAP performance data be compared with predetermined maintenance triggers so that it's clear upfront when cap maintenance should be considered In order to ensure that it will continue to meet its design objectives into the future.

01:48:16.000 --> 01:48:22.000
I believe our next step is taking questions. Am I correct?

01:48:22.000 --> 01:48:29.000
Yes, thank you so much for wrapping that up, Ashley. So now we're going to go over into the Q&A.

01:48:29.000 --> 01:48:34.000
If you have any questions, please post them in the Q&A and we will try to get through as many as possible.

01:48:34.000 --> 01:48:46.000
Before we finally wrap this up. So I'm going to go over one of the questions that has been answered just to see if one of our trainers would like to expand upon the answer.

01:48:46.000 --> 01:48:54.000
There's a question from Brad that says can Sorry, wrong question there.

01:48:54.000 --> 01:49:00.000
Sorry, there's an anonymous question that says, what did you mean by water column effects?

01:49:00.000 --> 01:49:12.000
Under placement disadvantages. And Mike, I believe you gave an answer to this, but I was just wondering if you'd like to expand upon it a little bit more.

01:49:12.000 --> 01:49:35.000
Yeah, I can expand on that. Really what's meant by that is that the spreader systems that were shown as the two proprietary proprietary placement methods have a thin lift a material so materials spread out instead of a big bulk placement like you would get out of a clamshell bucket or excavator.

01:49:35.000 --> 01:49:54.000
So that's that can be subject to additional effects from the water column. So if you're in a moving water environment, it may result in more drift of material, more material loss or turbidity, those effects can be controlled.

01:49:54.000 --> 01:50:07.000
By curtains or things like a moon pool. However, it's just an important consideration to keep in mind.

01:50:07.000 --> 01:50:17.000
Thank you so much, Mike. Did anyone else want to expand upon that?

01:50:17.000 --> 01:50:25.000
I have another question that is open right now. And it is four caps.

01:50:25.000 --> 01:50:34.000
Subject to tidal influence. How can we ensure best results interpretation? So this is referring to slide 45 in the first box. It says.

01:50:34.000 --> 01:50:50.000
Be careful of interpreting concentrations at cap water interface. Would anyone like to answer that?

01:50:50.000 --> 01:51:20.000
I'm not exactly sure what the question is, but I think it may be related to you know what I said about you know that your surface water is not necessarily representative of the dissolved phase material moving through your cap because there's so much flushing.

01:51:21.000 --> 01:51:32.000
Hi, this is Deirdre. I can also add to that. So I think when we talk about when we talk about Tidal influence.

01:51:32.000 --> 01:51:45.000
Sometimes what that means is that you'll have Surface water moving down into your cap and into the sediments and you also have groundwater moving up from the sediments and out into the surface water.

01:51:45.000 --> 01:52:04.000
And depending on what stage of the tide you're in, you can have this like back and forth movement And that's in the modeling at least that's handled one of two ways. One is you can explicitly simulate the change in groundwater

01:52:04.000 --> 01:52:34.000
Seepage rate or the rate direction of the flow with tidal oscillations or a variable groundwater flow. You can also keep the groundwater flow constant and this assess the influence of title oscillations through an increased dispersion term So, and then what the dispersion term does is it not only increases

01:52:36.000 --> 01:52:55.000
The transport of the chemicals up through the cap, but it also dilutes them. So there's this sort of balancing act right between the faster transport, but then also the dilution and You have to really test it out to see which one kind of drives that.

01:52:55.000 --> 01:53:07.000
And then as far as the compliance goes. Be careful of interpreting concentrations that the cap water interface. So that's right at the surface.

01:53:07.000 --> 01:53:18.000
And that surface concentration that's predicted by the model will be very highly dependent on what your boundary condition is.

01:53:18.000 --> 01:53:25.000
So you'd want to be like further into the cap, you know, in the bioturbation zone at the bottom of the bioturbation zone.

01:53:25.000 --> 01:53:37.000
And I think by staying away from that top grid cell that's right at the interface you can sort of avoid that process that's right at the interface.

01:53:37.000 --> 01:54:01.000
But as far as the title influence goes, again, it's there's sort of this play increased transport and then dispersion that we'll control. So as long as you're not right at that interface, I think you should be okay.

01:54:01.000 --> 01:54:27.000
Thank you, Tamara and Deirdre. All right, moving on, it looks like we have a couple of new questions posted in the Q&A One of the questions that someone asked is, is the purpose of sediment cap to prevent contaminants in the sediment layer from entering the surface water.

01:54:27.000 --> 01:54:33.000
Yes, that could be you want to limit the amount of flux to your water column.

01:54:33.000 --> 01:54:46.000
Sometimes, depending on your criteria, it's also to reduce the concentrations at the surface of your cap, which is where the benthic organisms are going to live and feed.

01:54:46.000 --> 01:54:54.000
And so you want to limit exposure to those organisms from the chemicals that are coming from the sediments below.

01:54:54.000 --> 01:55:04.000
And then also that impacts the food chain, right? So what are other organisms feeding on and you know, getting into the fish.

01:55:04.000 --> 01:55:20.000
But certainly reducing the flux to the surface water column is one of those Goals.

01:55:20.000 --> 01:55:29.000
Thank you so much again, Deirdre. I just want to check to see if anyone is able to answer this.

01:55:29.000 --> 01:55:40.000
I'm just going to take this one last question. Can I apply sediment cap chemical isolation to our river polluted wooden with acid mine drainage.

01:55:40.000 --> 01:56:01.000
Is anyone able to answer that? If not, we can move on.

01:56:01.000 --> 01:56:14.000
All right, I'm not seeing anyone coming off mute so We are going to move on. I'll go over one more question that is answered just to see if you're able to expand upon it.

01:56:14.000 --> 01:56:33.000
Someone asked, what has been shown to effectively supplement the missing settling and mixing data for Faith metric surveys conducted in title areas, and this refers to slide 56.

01:56:33.000 --> 01:56:39.000
Yeah, I can follow up with more information on that one.

01:56:39.000 --> 01:56:49.000
Most of the other tools included in that slide could be use to supplement the bathymetric data and evaluate mixing or settling.

01:56:49.000 --> 01:56:57.000
The sediment cap layers so things like the sub bottom profile sediment imaging.

01:56:57.000 --> 01:57:11.000
Along with sediment cores they they could all work to supplement that bath metric data the tool that's best fit is just going to be based on the project objectives.

01:57:11.000 --> 01:57:24.000
So you need to consider it on a case-by-case basis, but there's several tools that could help supplement.

01:57:24.000 --> 01:57:30.000
Thank you so much, Mike, for answering that. And at this time, we are going to wrap it up.

01:57:30.000 --> 01:57:35.000
So I just want to say Thank you to our expert trainers.

01:57:35.000 --> 01:57:42.000
For being here today and for their contribution to the ITRC document, please give them a round of applause.

01:57:42.000 --> 01:57:50.000
To yourself since we can't you hear you. And we would like to hear back from you today. So please be sure to fill out the online feedback form.

01:57:50.000 --> 01:57:56.000
That's linked on this last slide. When you fill out the feedback form and certify that you participated.

01:57:56.000 --> 01:58:05.000
You will receive a certificate of completion by email. If you need any further clarification on answers or would like to ask more questions.

01:58:05.000 --> 01:58:15.000
Feel free to email us at itrc at itrcweb. And we will follow up with our trainers to get your questions answered.

01:58:15.000 --> 01:58:35.000
Thank you