Fractured Bedrock Focus Area
navigational bar

Submit a Site

*Required Fields
Site Name and Location:
Site Name*:
City*:
State/Province:
Country*:
Contact Information:
First Name*:
Last Name*:
Address Line 1*:
Address Line 2:
City*:
State/Province:
Zip Code*: e.g. 12345 or 12345-6789
Country*:
Phone*: e.g. 123-123-1234
Fax: e.g. 123-123-1234
Email*:
Site Characteristics:
Briefly describe the hydrogeology of this site, including rock type, density, and orientation of the fractures, and ground water flow patterns:*

Identify the lateral and vertical extent of the plume.

helpTargeted Environmental Media*
Dense Non-aqueous Phase Liquids (DNAPLs)
Fractured Bedrock
Light Non-aqueous Phase Liquids (LNAPLs)

Major Contaminants*
Contaminant Name Maximum Contaminant Concentration (µg/L)
Site Characterization Technologies
Check those technologies which have been or are being used
Borehole Geophysics
Single Point Resistance
Natural Gamma
Caliper
Acoustic Televiewer
Video Camera Televiewer
Other
Fluid Loggings
Temperature
Conductivity/Resistivity
Unknown
Flow
Tracer (Brine)
Heat Pulse Flowmeter
Electromagnetic Flowmeter
Unknown
Surface Seismic Surveys
Reflection
Refraction
Unknown
Vertical Chemical Profiling
Packer Isolation
Cluster Wells
Multi-sampling port
Unknown
Pumping Tests
Fracture Trace Analysis
Surface Conductivity Surveys (EM)
GPR Surveys
Downhole Seismic Surveys
Coring
Tracer (dye) Test
Other
Comments:
Remedial Technologies
Check those technologies which have been or are planned to be used
Flushing (In Situ)
Surfactant
Water
Cosolvent
Unknown
Chemical Oxidation (In Situ)
O2
Fenton's Reagent
Ozone
Permanganate
Iron Activated Persulfate
Base Activated Persulfate
Heat Activated Persulfate
Hydrogen Peroxide
Unknown
Fracturing
Thermal Treatment (In Situ)
Steam Enhanced Extraction
Electrical Resistive Heating
Hot Water Injection
Radio Frequency Heating
Conductive Heating
Unknown
Pump and Treat
Soil Vapor Extraction
With Air Stripping
In Unconsolidated Overburden
In Dewatered Zones
In Fractured Bedrock Vadose Zone
Unknown
Multi Phase Extraction
Bioremediation (In Situ)
Aerobic Oxidation
Reductive Dechlorination (In Situ Bioremediation)
Unknown
Other
Comments, including length of use, measurements of performance, clean up trends:
Remediation Goals
Identify cleanup goals, including ground water cleanup levels:
Status
Current status, including ground water contamination levels and trends:
Lessons Learned
   

http://clu-in.org/fracrock/
Form last modified: November 8 2010 13:01 /18:01 UTC